  sensor solutions /// M5200 page 1 08/2016 M5200 industrial pressure transducer specifications ? wide temperature range ? compact ? variety of pressure ports and electrical configurations ? optional stainless steel snubber ? ce compliant and weatherproof ? gage, sealed, compound the M5200 pressure transducers from the microfused line of meas, with their modular design, offer maximum flexibility for different configurations. this latest series sets a new price performance standard for demanding commercial and heavy industrial applications. this series is suitable for measurement of liquid or gas pressure, even for difficult media such as contaminated water, steam, and mildly corrosive fluids. the wetted material is made of either 17 -4 ph or 316l stainless steel and the transducers durability is excellent with no o-rings, welds or organics exposed to the pressure media. the M5200 is weatherproof and exceeds the latest heavy industrial ce requirements including surge protection. the circuit is protected from reverse wiring at input and short circuit at output. this product is geared to the oem customer for low to mid volumes. meas stands ready to provide a custom design of the M5200 where the volume and application warrants. additional configurations not listed are either available or possible. please inquire for further information.
M5200 industrial pressure transducer sensor solutions ///M5200 08 /2016 page 2 features ? heavy industrial ce approval ? 10 v/m emi protection ? reverse polarity protection on input ? short circuit protection on output ? 0.25% accuracy ? 1.0% total error band ? compact outline ? -40c to +125c operating temperature ? weatherproof applications ? industrial process control and monitoring ? advanced hvac systems ? refrigeration systems ? automotive test stands ? off-road vehicles ? pumps and compressors ? hydraulic/pneumatic systems ? agriculture equipment ? energy generation and management standard ranges range (psi) range (bar) gage sealed compound 0 to 050 0 to 3.5 ? ? 0 to 100 0 to 007 ? ? 0 to 010 ? ? 0 to 200 ? ? 0 to 300 0 to 020 ? ? 0 to 500 0 to 035 ? ? 0 to 01k 0 to 070 ? ? ? 0 to 03k 0 to 200 ? ? ? 0 to 05k 0 to 350 ? ? ? 0 to 07k 0 to 500 ? ? ? 0 to 10k 0 to 700 ? ? ? 0 to 15k 0 to 01k ? ? ? intermediate ranges available upon request
M5200 industrial pressure transducer sensor solutions ///M5200 08 /2016 page 3 performance specifications ambient temperature: 25c (unless otherwise specified) parameters min typ max units notes accuracy (combined non linearity, hysteresis, and repeatability) -0.25 0.25 %f.s. bfsl isolation, body to any lead 100 m @500vdc dielectric strength 2 ma @500vac, 1min pressure cycles 1.00e+6 0~fs cycles proof pressure 2x rated burst pressure 5x 20k psi rated long term stability (1 year) -0.25 0.25 %f.s. total error band (17-4ph) -1.0 1.0 %f.s. over compensated temperature range total error band (316l, 3k psi) -1.5 1.5 %f.s. over compensated temperature range total error band (316l, >3k psi) -2.0 2.0 %f.s. over compensated temperature range compensated temperature - 20 +85 c operating temperature - 40 +125 c except cable 105c max storage temperature - 40 +125 c except cable 105c max load resistance (r l ) r l > 100k voltage output load resistance (r l ) < (supply voltage -9v) / 0.02a current output current consumption 5 ma voltage output rise time (10% to 90%) <2ms (voltage output); <3ms (current output); without snub ber wetted material 17 -4ph or 316l stainless steel port, 316l stainless steel sn ubber gage pressure reference vent under 1k psi, customer to ensure venting through mating co nnector bandwidth dc to 1khz (typical) shock 50g, 11msec half sine shock per mil-std-202g, method 213b , condition a vibration 20g, mil-std-810c, procedure 514.2, fig 514.2-2, curv e l for custom configurations, consult factory. notes compensated temperature: the temperature range over wh ich the product will produce an output proportional to pr essure within the specifie d performance limits. operating temperature: the temperature range over which th e product will produce an output proportional to press ure but may not remain within the specified performance limits. storage temperature: the temperature range over which the p roduct can be stored safely in occasions without pressure applied or power input and remains rated performance. beyond this tempe rature range may cause permanent damage to the produc t. all configurations are built with supply voltage reverse and output short-circuit protections. ce compliance en 55022 emissions class a & b iec 61000-4-2 electrostatic discharge immunity (8kv co ntact/15kv air) iec 61000-4-3 radiated, radio-frequency electromagnetic field immunity (10v/m, 80m-1ghz) iec 61000-4-4 electrical fast transient immunity (1kv) iec 61000-4-5 surge immunity (v+ to v- : 2kv/42; l to case: 1kv / 12; v - to v 0 : 1kv/42) iec 61000-4-6 immunity to conducted disturbances ind uced by radio frequency fields (150k~80mhz, 10v level for voltage output models, 3v level for current output model) iec 61000-4-9 pulse magnetic field immunity (100a/m peak) for all ce compliance tests, max allowed output deviation 1.5 %f. s.
M5200 industrial pressure transducer sensor solutions ///M5200 08 /2016 page 4 dimensions [mm] note: refer to installation instructions for recommended t orque. code connection type dim a 1 cable 2 ft 2.19 [55.6] e cable 3 ft 2.19 [55.6] 2 cable 4 ft 2.19 [55.6] 3 cable 10 ft 2.19 [55.6] 4 packard connector a 2.25 [57.2] 5 bayonet connector 2.11 [53.6] 6 form c 1.95 [49.5] 7 form a 2.10 [53.3] 9 packard connector b 2.25 [57.2] d m12 connector 1.95 [49.5] m cable 1 m 2.19 [55.6] n cable 2 m 2.19 [55.6] p cable 5 m 2.19 [55.6] r cable 10 m 2.19 [55.6] a amp connector 2.10 [53.3] s sumitomo connector 1.95 [49.5] c 1/2" npt conduit 2.10 [53.3] pressure port type code port dim b dim c ref. 2 1/4-19 bspp 0.472 0.366 [11.94] [9.3] 3 g3/8 jis b2351 0.540 0.366 [13.72] [9.3] 4 7/16-20unf male sae j1926- 2 straight thread o- ring buna-n 90sh-904 0.433 0.366 [11.0] [9.3] 5 1/4-18 npt 0.600 0.366 [15.24] [9.3] 6 1/8-27 npt 0.390 0.366 [9.91] [9.3] b g1/4 jis b2351 0.472 0.366 [11.94] [9.3] e 1/4-19 bspt 0.500 0.366 [12.7] [9.3] f 1/4-19 bspp female (without snubber) 0.621 0.366 [15.77] [9.3] p 7/16-20unf female sae j513 straight thread with integral valve depressor 0.430 0.444 [10.92] [11.28] n 7/16-20unf female sae j513 straight thread 0.430 0.444 [10.92] [11.28] q m10 x 1.0 mm iso 6149 -2 0.374 0.366 [9.5] [9.3] s m12 x 1.5 mm iso 6149-2 0.433 0.366 [11.0] [9.3] u g/14 din 3852 form e gasket din3869-14 nbr 0.472 0.445 [11.94] [11.3] w m20 x 1.5 mm iso 6149-2 0.551 0.366 [14.0] [9.3] g m14 x 1.5 mm iso 6149-2 0.433 0.366 [11.0] [9.3] 1 4 3 2 2 1 3 2 1 3 21 3 2 1 3
M5200 industrial pressure transducer sensor solutions ///M5200 08 /2016 page 5 wiring connection +supply -supply p ref vent bayonet a b f packard, a a b hole through connector packard, b b a hole through connector cable red blk in cable 1/2npt conduit red blk in cable m12 1 3 hole through connector amp/te 1 2 hole through connector form c 1 2 threads through connector form a 1 2 threads through connector sum itom o 1 2 hole through connector connection +supply +output common nc. pins p ref vent bayonet a b c d,e f packard, a a c b hole through connector packard, b b c a hole through connector cable red wht blk in cable 1/2npt conduit red wht blk in cable m12 1 2 3 4 hole through connector amp/te 1 3 2 hole through connector form c 1 2 3 4 threads through connector form a 1 3 2 4 threads through connector sum itom o 1 3 2 hole through connector current output wiring voltage output wiring nc. pins c,d,e c c 2,4 3 3,4 3,4 3 notes: 1. nc pins are reserved for factory use only. customers should not use these connections . 2. for cable connection, the drain wire is internally terminated to pressure port.
M5200 industrial pressure transducer sensor solutions ///M5200 08 /2016 page 6 connection types note: transmitter of gage pressure type requires vent to atmos phere on the pressure reference side. this is accomplished via cable from the transmitter (the end of the cable should be terminated t o clean and dry area) or through the customer mating co nnector/cable assembly which has internal vent path. suggested vented m12 mating connector p/n mb12fwaff04st -4 and mb12fwaff04st-3 at www.finecables.com for 0.157~0.236 and 0.236~0.315 diameter cable respectively. weatherproof note: weatherproof ratings are met when the mating connectors are installed properly and the cable termination is to dry a nd clean area. outputs connection description mating housing p/n mating terminal p/n rubber seal p/n bayonet bayonet ptih-10-6p or equiv pt06a-10-6s mil-c-26482 - - packard 3-pin metri-pack 150 12078090 12103881, qty 3 - cable & 1/2npt conduit 4-wire,22 awg, shielded, pvc jacket, 105 degc - - - m12 binder series 713, 09 3431 77 04 or equiv 4-pos female connector - - amp/te amp / te 3-pin econoseal j series 174357-2 & 174358-7 171630-1 (awg 20~24) 171662-1 (awg 16~20) qty 3 172746-1 (awg 20~24) 172888-2 (awg 16~20) qty 3 form c industrial standard 9.4mm form c hirschmann 933 024-100,or, atam kd046000b7 (seal incl.) - hirschmann 730 185-002 form a din en 175 301-803-a 18mm hirschmann 931 969-100,or, atam ka245000b4 (seal incl.) - hirschmann 730 801-002 sum itom o sumitomo 3-pin hv040 6189-6907 8100-3067 (awg 20~22) 8100-3068 (awg 16~18) qty 3 7165-1075 (ins. dia 1.1~1.6mm) 7176-0621 (ins. dia 1.6~1.9mm) 7165-0622 (ins. dia 1.8~2.2mm) qty 3 connection types connection ip code bayonet ip67 packard ip66 cable ip67 1/2npt conduit ip67 m12 ip67 amp/te ip67 form c ip65 form a ip65 sum itom o ip67 weather-proof rating code output signal supply voltage 3 0.5 - 4.5v ratiometric 5 0.25v protected to 30v 4 1 - 5v 8 - 30v 5 4 - 20ma 9 - 30v 6 0 - 5v 8 - 30v 7 0 - 10v 12 - 30v 8 1 - 6v 8 - 30v 9 0.5 - 4.5v 5 - 30v
M5200 industrial pressure transducer sensor solutions ///M5200 08 /2016 page 7 ordering information m52 3 1 - 0 0 00 0 5 - 100p g model output signal connection type - port material snubber 00 label pressure port - pressure range pressure type m52 3 = 0.5 C 4.5v ratiometric 4 = 1 C 5v 5 = 4 C 20ma 6 = 0 C 5v 7 = 0 C 10v 8 = 1 C 6v 9 = 0.5 C 4.5v 1 = cable 2 ft e = cable 3 ft 2 = cable 4 ft 3 = cable 10 ft 4 = packard connector a 5 = bayonet connector 6 = form c 7 = form a 9 = packard connector b d = m12 connector m = cable 1 m n = cable 2 m p = cable 5 m r = cable 10 m a = amp connector s = sumitomo connector c = 1/2 npt conduit - 0 = 17-4ph 1 = 316l ss 0 = no snubber 1 = oxygen clean b40.1 level iv 2 = with snubber 00 0 = adhesive label 1 = laser marking 2 = 1/4-19 bspp 3 = g3/8 jis b2351 4 = 7/16-20unf male sae j1926-2 straight thread o-ring buna- n 90sh-904 5 = 1/4-18 npt 6 = 1/8-27npt b = g1/4 jis b2351 e = 1/4-19 bspt f = 1/4-19 bspp female p = 7/16-20unf female sae j513 straight thread with integral valve depressor n = 7/16-20unf female sae j513 straight thread q = m10 x 1.0 mm iso 6149-2 s = m12 x 1.5 mm iso 6149-2 u = g1/4 din 3852 form e gasket din3869-14 nbr w = m20 x 1.5 mm iso 6149-2 g = m14 x 1.5 mm iso 6149-2 - 050p 100p 200p 300p 500p 01kp 03kp 05kp 07kp 10kp 15kp 3.5b 007b 010b 020b 035b 070b 200b 350b 500b 700b 01kb g = gage s = sealed (1k psi) c = compound note : for sumitomo and 1/2 npt conduit, contact factory f or additional information. compound pressure range is -14.7 to xxxps ig or -1 to xxxbarg. (e.g. 200pc: -14.7 to 200psig, 020 bc: -1 to 20barg) refer to online installation instruction for recomm ended torque. installation instructions will no longer be shipped with unit delivery. this document is available on our website in english and chinese. te.com/sensorsolutions measurement specialties, inc., a te connectivity company. measurement specialties, te connectivity, te connectivity (logo) and ev ery connection counts are trademarks. all other logos, products and/o r company names referred to herein might be trademarks of their respective owners. the information given herein, including drawings, illustrations an d schematics which are intended for illustration purposes only, is believe d to be reliable. however, te connectivity makes no warranties as to its accuracy or completeness and disclaims a ny liability in connection with its use. te connectivitys obligations sh all only be as set forth in te connectivitys standard terms and conditions of sale for this product and in no case will t e connectivity be liable for any incidental, indirect or consequ ential damages arising out of the sale, resale, use or misuse of the product. users of te connectivity products should make their own evaluat ion to determine the suitability of each such product for the specific ap plication. ? 2015 te connectivity ltd. family of companies all rights reserved. north america measurement specialties, inc., a te connectivity company 45738 northport loop west fremont, ca 94538 tel: 1-800- 767 -1888 fax: 1-510-498-1578 sales: pfg.cs.amer@meas-spec.com europe measurement specialties (europe), ltd., a te connectivity company 26 rue des dames 78340 les clayes-sous-bois, france tel: +33 (0) 130 79 33 00 fax: +33 (0) 134 81 03 59 sales: pfg.cs.emea@meas-spec.com asia measurement specialties (china), ltd., a te connectivity company no. 26 langshan road shenzhen high-tech park (north) nanshan district, shenzhen 518057 china tel: +86 755 3330 5088 fax: +86 755 3330 5099 sales: pfg.cs.asia@meas-spec.com